Views: 0 Author: Site Editor Publish Time: 2026-11-23 Origin: Site
ASTM D1785 is the standard specification for rigid PVC pressure pipe made in Schedule 40, Schedule 80 and Schedule 120. It sets the requirements for the pipe itself: material, dimensions, pressure testing and marking. This guide explains what the standard covers, what it leaves out, which related standards apply, and what to include when you specify or buy ASTM D1785 pipe.
ASTM D1785 specifies PVC pipe made in Schedule 40, 80 and 120 sizes and pressure-rated for water. It is intended for pressurized liquids that are chemically compatible with PVC. Inch-pound values are the standard values; the SI values in parentheses are conversions for information only.
The standard is revised from time to time. At the time of writing, the ASTM Store lists D1785-26 as the active edition, and earlier editions such as D1785-21a are marked historical. Always confirm the edition your project specification requires.
Classification of PVC pipe materials and PVC pipe
A system of nomenclature for PVC pipe
Requirements and test methods for materials, workmanship, dimensions, sustained pressure, burst pressure, flattening and extrusion quality
Methods of marking
Fittings, valves and joints. These follow their own standards (see the table below).
Compressed air or gas. The standard is for pressurized liquids. Compressed gases store far more energy than liquids, so some manufacturers do not allow pneumatic testing of their products.
Venting of combustion gases.
CPVC pipe. CPVC Schedule 40 and 80 pipe is covered by ASTM F441/F441M.
Drinking-water approval. D1785 is not a potable-water certification. Check for NSF or local approvals.
Material. Pipe is made from PVC compounds classified under ASTM D1784, for example cell class 12454. D1785 recognizes six type, grade and design stress designations for the pipe material, based on four hydrostatic design stress values. The designation is part of the pipe marking, for example PVC 1120.
Performance tests. The standard sets requirements for sustained pressure, burst pressure, flattening and extrusion quality. Together they check both the long-term pressure strength of the pipe and the quality of the extrusion.
Marking. Compliant pipe is printed with its nominal size, PVC material designation, Schedule, ASTM D1785, the manufacturer's name or trademark and a production code. Pipe approved for potable water also carries the approval mark. A typical line reads: 2 IN PVC 1120 SCH 80 ASTM D1785, followed by the manufacturer and production code.
Pipe color alone does not prove the material, Schedule or conformity. Check the printed marking and the supplier's documents.
"Schedule" is a wall thickness series. At each nominal size the outside diameter is the same in every Schedule, and the wall thickness grows with the Schedule number.
Schedule 40: the standard wall, with the largest bore. Common in water supply and irrigation.
Schedule 80: a thicker wall and a smaller bore. Common in industrial piping and where extra strength is needed.
Schedule 120: the heaviest wall of the three, with the smallest bore, used in specialized systems. It is less common, and availability varies by size, so confirm it with your supplier.
Pressure capacity depends on pipe size, material classification, temperature and the applicable design requirements, so it cannot be read from the Schedule number alone. For a side-by-side comparison, see our guide to Schedule 40 vs Schedule 80 PVC pipe.
D1785 gives the outside diameter, outside diameter tolerance, minimum wall thickness and wall thickness tolerance for each nominal size. Dimensions are determined according to ASTM D2122. The nominal size is a label, not a measurement: 2″ pipe has an outside diameter of 60.32 mm.
Nominal size | OD (mm) | OD tolerance (mm) | Sch 40 min. wall (mm) | Sch 80 min. wall (mm) |
|---|---|---|---|---|
1″ | 33.40 | ±0.13 | 3.38 (+0.51) | 4.55 (+0.53) |
2″ | 60.32 | ±0.15 | 3.91 (+0.51) | 5.54 (+0.66) |
4″ | 114.30 | ±0.23 | 6.02 (+0.71) | 8.56 (+1.02) |
These are three example sizes. For every size from 1/2″ to 24″, including inside diameter calculations, see our full PVC pipe dimensions chart.
ASTM D1785 pressure ratings are based on water service at 73°F (23°C). PVC pressure capacity decreases as operating temperature increases. The allowable working pressure at elevated temperatures depends on the pipe manufacturer's temperature derating data, material classification and service conditions. Always check the manufacturer's specifications before selecting PVC pipe for higher-temperature applications. Also consider surge pressure, including water hammer, when designing the system.
The pressure limit of a finished system is set by its lowest-rated component. A heavier Schedule of pipe does not raise the rating of a lower-rated valve, fitting or joint. Rating tables by size are in our Schedule 40 vs Schedule 80 guide.
Standard | What it covers |
|---|---|
ASTM D1784 | Classification of rigid PVC and CPVC compounds |
ASTM D2122 | Method for determining dimensions of thermoplastic pipe |
ASTM D1598 | Sustained pressure (time-to-failure) test |
ASTM D1599 | Short-time burst pressure test |
ASTM D2466 | Schedule 40 PVC socket-type fittings |
ASTM D2467 | Schedule 80 PVC socket-type fittings |
ASTM D2464 | Schedule 80 PVC threaded fittings |
ASTM D2241 | PVC pressure pipe in the SDR series |
ASTM F441/F441M | CPVC pipe, Schedule 40 and 80 |
D1785 vs D2241. D1785 sizes pipe by Schedule, so wall thickness steps up with the Schedule number. D2241 uses SDR (standard dimension ratio), where the ratio of outside diameter to wall thickness stays constant. Choose the standard your project drawings call for.
A purchase order that only says "Schedule 80 PVC pipe" is incomplete. Include:
Nominal pipe size
Schedule (40, 80 or 120)
The ASTM D1785 edition required by the project
Working pressure and surge pressure
Normal and maximum liquid temperature
The liquid and its concentration, so compatibility can be checked
Connection type (socket, rubber ring or plain end) and matching fittings
Required certifications and documents, such as NSF approval for potable water
When the pipe arrives, compare the printed marking with the order before cutting or joining.
Huasheng Pipeline is a manufacturer with more than 35 years of industry experience. We make ASTM D1785 PVC pipe in Schedule 40 and Schedule 80 from 1/2″ to 24″, with matching ASTM fittings, OEM service and samples. Certificates listed on our Schedule 80 product page include SGS, NSF, ISO and CE. Contact us for the documents that apply to your order.
Looking for ASTM D1785 pipe? See our gray Schedule 80 PVC pipe and Schedule 40 PVC pipe, or the matching Schedule 40 fittings and Schedule 80 fittings.
Contact Huasheng for a quotation
No. ASTM D1785 covers Schedule 40, Schedule 80 and Schedule 120 PVC pipe. Schedule 40 is one of the three wall thickness series in the standard.
No. It applies to pipe only. Fittings, valves and joints must meet their own standards, such as ASTM D2466, D2467 and D2464 for PVC fittings.
No. For potable water, look for NSF or other approvals required by local codes, shown in the pipe marking.
D1785 uses the Schedule system, with wall thickness set by Schedule number. D2241 uses SDR, where the diameter-to-wall ratio is constant.
No. The standard is for pressurized liquids. Compressed air and gases store much more energy, which creates a safety hazard if the system fails.
ASTM D1785 Explained: PVC Pipe Standard, Requirements And Specifications
Schedule 40 Vs Schedule 80 PVC Pipe: Differences, Pressure Ratings And How To Choose
Why UPVC Pipes Are the Preferred Choice for High-Rise Building Plumbing Systems
PVC Pipe Full Form: Meaning, Types, Standards & Applications
UPVC Pipe Full Form: Meaning, Types, Standards & Applications
How to Store PVC Pipe: Indoors, Outdoors, Stacking & Long-Term Tips
Products